Performance description for intermediate savings

Insulation between the rafters

Component, insulation: thermal barrier coating between rafters

  • Share of rafters [%] Total area: over 10 to 15
  • Insulation: mineral wool
  • Abbreviation Insulation: MW
  • Abbreviation Area of ​​application Insulation: DZ - Insulation between rafters / 2-shell roof / top floor
  • Standard insulation material: DIN EN 13162
  • Delivery form Insulation: mat / felt
  • Total number of layers: 1
  • Thickness [mm] Insulation layer: 180
  • Rated thermal conductivity [W / (mK)]: 0.032
  • Class Fire behavior: A1 / A2 (non-combustible) DIN 4102-1
  • Impact insulation: stumped

Cost 3,956 €

vapor barrier

  • Substructure Roof covering / wallcovering: Diffusion-inhibiting layer sd value above 0.5 to less than 100 m
  • Building material, sealing: Polyethylene film (PE)
  • Thickness [mm] plastic film: 0.3
  • Seam attachment: glue / weld seams and joints
  • Component, extension: roof inside

Cost 1.215 €

Interior lining of the roof surface with plasterboard

Clothing: Dachschrägen- / Deckenbekleidung

  • Ventilation / permeability Component: not specified
  • Installation position: inclined
  • Angle [degrees] Inclination: 30.00
  • Load [kN / m2] ceiling: up to 0.15
  • Fire resistance class: F 30 - A
  • Mounting base Drywall work: wooden rafters
  • Function / connection ceiling: connection with roof construction
  • Building material, substructure: without substructure
  • Insulation: without insulation
  • Separating layer: without specification
  • Building material, clothing: gypsum fiber board
  • Property covering / clothing: without indication
  • Thickness [mm] gypsum fiberboard: 10
  • Number of planking layers: single-ply
  • Attachment clothing: with hollow steel nails, hot-dip galvanized
  • Shock treatment: stump butt
  • Quality level surface: Q2 (standard version)

Cost 3.675 €