Stainless steel chimney Performance description

Chimney - execution

  • Component, exhaust system: chimney
  • Construction exhaust system: multi-shell
  • Type exhaust system: Kit according to building inspectorate approval
  • Number of trains exhaust system / ventilation shaft: single-entry
  • Duct: without specification
  • Height [m] exhaust system: up to 6
  • Plant operating mode: room air dependent
  • Temperature class: T 100 (degree C)
  • Operation fireplace: negative pressure
  • Gas-tightness class: N 2 (3 l / (sm2), -20 Pa)
  • Corrosion resistance class: 3 (solid / liquid / gaseous)
  • Operating mode exhaust system: GW3 (damp, soot fire)
  • Soot fire resistance class: G (soot fire resistant)
  • Internal cross section exhaust system: round
  • Diameter / Dimensions L / W [cm] Exhaust system: 14
  • Location component: externally grown
  • Range of thermal resistance [m2K / W] Exhaust system: 0.11 to 0.65
  • Distance [mm] to combustible components: 50.00